Jaguar XJ6 / XJ12 Series 3XJ6 S3 · 1979-1992 · 4.2 and 3.4 six-cylinder, 5.3 V12 HE; Daimler Sovereign and Double-Six
jagaux.com

Jaguar XJ6 Series 3 Blower Motor Not Working

When both blowers on a Series 3 stop together, it's almost always the supply, not the motors: the 50 A fan fuse or its holder, then the climate feed fuses, an earth or the four-relay pack. I'd select Defrost with the engine warm first, then fit a new fan fuse and squeeze its clips before buying anything.

8likely causes

How bad is it · Safe to drive

Safe to drive — keep the screen clear

Nothing here harms the engine. Without the fans the screen mists quickly in cold or wet weather, and only ram air at speed will clear it.

Jagaux Doctor · typical causes and checks — not a diagnosis of any one car jagaux.com/doctor/cases/xj6-s3/blower-motor-not-working/

Get a diagnosis for your XJ6 / XJ12 Series 3

This page covers the usual causes. The Doctor works on your car: describe what it does and what has already been replaced, and it narrows these down to your symptoms, model year and fuse layout — which check to do first, and what not to buy yet.

This page lists the usual causes — it is not a diagnosis of your car.

Which one applies to yours depends on your symptoms, your model year and what has already been done to it.

01

Likely causes, most common first

Read the check cost before the odds: a free check that rules a cause out beats a likely guess that costs money.

1

The 50 A fan fuse and its holder

Both blowers run from one 50 A fuse — fuse 16 in the auxiliary fuse panel on the 1987 layout. Lucas glass fuses break inside the cap or at a soldered end and still look good, and the cradle clips loosen, heat up and burn the wires behind them.

How to tell

Both fans dead on every setting while the flaps and servo can still be heard moving; fans that come back when the fuse is touched. Fans that quit after driving through deep water, or that come and go before dying, point at the clips.

How to check

Don't trust your eyes or an ohmmeter: fit a new fuse, squeeze the cradle clips so they grip, then check 12 V on both sides with a test lamp under load. Drop the holder and look at the wires behind it. If the wires behind the cradle have overheated, they barely make contact even with a new fuse in place.

The fix

A new fuse and clean, tight clips. A scorched holder or a loose wire behind it is soldered or rewired; a thin-wire in-line bodge is replaced with proper cable. To keep the cradle, take it apart, solder the crimped wire ends and tin the contact faces. Don't split the load across two smaller fuses in parallel: they never share the current, and one ends up carrying it all unprotected.

likely a fuse
2

Fans held off because the water at the heater is cold

When heating, a temperature switch on the heater inlet pipe keeps the fans off until the coolant reaches about 41 °C; Defrost overrides it. If the vacuum heater valve sticks shut, or air sits in the heater core, that pipe never warms and the fans stay off or blow cold.

How to tell

Fans run in Defrost but not in Lo or Auto, or only once the engine is fully hot; the heater hose from the bulkhead stays cool.

How to check

Feel both heater hoses at the bulkhead with the engine hot. Pull the vacuum line and move the valve lever by hand. To prove the switch, unplug it and bridge its two wires — as a test only.

The fix

Free a sticking valve with penetrating oil and work it, or fit a new one. After a coolant change, with the engine warm and the front raised, hold the valve shut by hand for about ten seconds and let go to clear the air.

likely a heater valve
3

The climate feed fuses, hidden in-line fuses and earths

The relays, mode switch and amplifier take their own smaller feed, and in-line fuses hide behind the console side panels and knee ducts. With that feed gone the system acts as if it were switched off, even with a good 50 A fuse. A corroded earth does the same, or keeps blowing the fan fuse.

How to tell

No relay clicks at all; the fans run when a relay is pressed by hand; fans and servo dead together. A feed fuse that blows the instant it's replaced points to a short in the sensor wiring rather than the fans.

How to check

Measure both sides of every fuse in both footwell panels, then look behind the console side panels and knee ducts for in-line holders gone green. Clean the earth points in the footwells. If it blows at once, unplug the wire at the in-car temperature sensor: a chafed white/blue wire between the in-car and ambient sensors can short to earth.

The fix

Renew the blown feed fuse, clean the corroded in-line holder, sand and grease the earth.

plausible free to clean; a fuse
4

The four-relay fan pack

Fan speeds come from a pack of four relays (C46179) and a dropper resistor unit, low on the left of the climate unit behind the console side panel. A dead relay usually costs one or two speeds rather than all of them; a stuck one keeps the fans running.

How to tell

Lo and Auto dead but Hi and Defrost fine, or low speed only whatever the setting; a click or a spark at the pack connector. Fans that keep running with the switch at Off, or with the key out, are usually a relay in the pack stuck closed: the motor feed is live all the time and only the relays switch it.

How to check

Test lamp on the heavy brown/white feed at the pack. With the ignition on and the switch at Hi or Defrost, jumper brown/white to green/slate: the fans should run flat out. In Auto at 65, wiggle and tap each wire at the pack. For fans that won't stop, pull the yellow, blue and red wires at the pack one at a time and see which stops them. Some cars have three relays in the pack and a separate round Low relay behind it, which fails regularly.

The fix

Clean and tighten the pack connector, restore a missing earth to the Hi relay, or fit a refurbished pack. A metal relay pack can be opened and its points cleaned; a plastic one is replaced.

plausible a refurbished relay pack
5

A microswitch in the mode switch

The Off, Lo, Auto, Hi and Defrost positions work through small microswitches on a cam (AEU 2743). A cracked or sticking microswitch leaves the fans dead in every position, or running when they should stop.

How to tell

No relay clicks in any position although the feed reaches the switch; fans that start only when the knob is rocked. A sticking Off microswitch can also leave the fans running at low speed with the switch at Off while every other position works.

How to check

Confirm power at the switch feed first, then at each microswitch output with the switch assembled.

The fix

Replace the microswitch (RTC675) or the whole switch panel with a good used one. It means dash work: photograph everything and mind the fibre-optic strands. Short of dash removal, a sticking microswitch can sometimes be freed with a long screwdriver from the right footwell and a shot of PTFE spray — a temporary cure.

plausible a used switch panel, plus dash work
6

The climate amplifier and its setting

In Auto the fan speed follows the amplifier and servo; Defrost and manual Hi bypass them. An amplifier set too far one way can hold the fans at a quarter speed, and a failing one leaves only Defrost working.

How to tell

Speed doesn't change with the temperature knob while Defrost runs flat out; no servo sound when the knob is flicked.

How to check

With the cabin between 65 and 85 °F, flick the knob between 65 and 85 and listen for the servo each time. The adjustment screw is fine-tuning only — turn it in small steps.

The fix

Turn the adjustment screw clockwise; if the servo won't respond, try a known-good amplifier. The original amplifier is a common failure; a replacement unit is the reliable cure.

unlikely free to adjust; an amplifier
7

The fuse keeps blowing or the fans won't stop

A new fan fuse that blows at once points to a short or a burnt motor, not the amplifier. Wiring from an added auxiliary cooling-fan circuit can feed back into the climate circuit and blow its fuse; a broken wire at a fan touching metal keeps it running.

How to tell

The fuse goes straight away; fans run with the switch off; trouble began after electrical work. On a car with the auxiliary radiator fan, a shorted isolating diode on the small board near that fan can keep the blowers running at low speed.

How to check

Disconnect the motor wiring and reconnect one at a time. Check any added fan wiring for crossed wires, and the small wires at each fan housing for chafing.

The fix

Correct the crossed or chafed wire, then fit a new fuse.

unlikely free to trace
8

A blower motor itself

There are two blowers, one each side, so both rarely die at once. One weak or dead motor shows as poor flow from one side; worn brushes are a known cause. On the 1987–92 V12 with Delanair Mk III, each fan has its own electronics in the housing, and water from blocked drains can kill them.

How to tell

Air from one side only; on Mk III, fans stuck on high or never switching off.

How to check

Feed 12 V straight to a motor to split a fan fault from a supply fault. Where each blower has its own fuse, pull one at a time with the switch on Hi and listen. One dead fan is usually local to that side; both dead together send you back to the fuse, relays and resistor unit.

Worth checking

Worth trying: new brushes or a good used motor; on Mk III, a known-good fan unit. On a Mk III fan board, check the small diode as well as the Darlington transistor.

unlikely a used blower motor
02

The order to check them in

The point of the order is money: each step either rules a cause out or makes the next one worth doing. Green is free, amber costs a little, red is the one to arrive at last.

1

Engine warm, select Defrost

Defrost runs the fans flat out and bypasses the water switch and the amplifier. If they run here, the supply is fine — look at the heater water and the settings.

free
2

Fit a new 50 A fan fuse

Fuse 16 in the auxiliary panel on the 1987 layout. Squeeze the cradle clips and test both sides with a lamp, not a meter.

a fuse
3

Check the feed fuses and earths

Both footwell fuse panels, the in-line fuses behind the console side panels and knee ducts, and the earth points.

a test lamp
4

Prove the fans at the relay pack

Brown/white should be live. Jumper it to green/slate with the switch on Hi: if the fans run, the motors are fine.

a jumper wire
5

Wiggle the relay pack in Auto at 65

Tap the pack and move each wire with the engine running; a speed that comes and goes is the connector or a relay.

free
6

Mode switch, amplifier, motors

Only after the above. The switch needs the dash apart; the amplifier is best tested by swapping in a known-good one.

parts plus dash work
03

The fuses named above — where they sit

The highlighted position is the one the procedure talks about. Pulling a fuse is a stop-gap, never a repair: check what the circuit feeds before you pull it.

F1650 A — Shared feed for both blower motors and the climate unit — when both fans die together, renew it and tighten its clipsAuxiliary Fuse Panel (Right Footwell)

We have no drawing of this box for this car — find them on the legend printed on the lid of the box itself.

04

What it usually isn't

Don't spend money here first:

Only three fan speeds when heating — the fourth comes with cooling.
Fans waiting on Lo or Auto from a cold start — normal until the coolant warms; Defrost runs them at once.
A medium speed that sounds as fast as high in hot weather — often nothing wrong.
Both blower motors failing at the same moment — when both stop together, look at the supply.

None of these sound like your XJ6 / XJ12 Series 3?

Describe what yours does and what has already been replaced. The Doctor works through the same cases against your symptoms and model year, and tells you which check to do first.

05

On jagaux.com

Ratings, fuse numbers and torque figures vary by model year and market. Read the legend on your own car before pulling anything, and use the figures in the manual for your car, not the ones in a video.

06

More Jaguar XJ6 / XJ12 Series 3 faults

blower-motor-not-working

Check your VIN: exactly which car you have and which bulletins apply to it.

Use this code to get 5% discount!

jagaux5

Your exclusive code is ready! Copy it now!

Get 5% off now!
🛒 0 items · € 0.00 Checkout →